1/12/2024 0 Comments Zoiper 3.15 for windows 10I have also tested pinging between the two destinations and found that the pings and their responses are timing out.ĭoes anyone have any idea as to what the problem is? It seems to possibly be a network problem possibly caused by our router (which is a Cisco ASA5505 running the most recent version of its firmware). The problem I am having, however, is that although the UEs that I am testing send a “REGISTER” request to 192.168.1.12, the local IP of our Asterisk/FreePBX Server, we get no response to the REGISTER message. I am using FreePBX 13.0.191.11 which utilizes Asterisk 13.12.1 and I have been able to get multiple desktop clients connected and calling successfully. I am using an LG G3 VS985 and a iPhone 6S+, both of which support SIP when in VoLTE mode.By setting the P-CSCF of one of the bearers of the network setup on the instrument to the address of a SIP server, I can have the UE, or cellphone, connect to that server to provide a given set of services, such as SIP.This test set has an IP address of 192.168.1.60, and gives the smartphone an IP address of 192.168.1.51 and/or 192.168.1.52 depending on the setup. This allows me to create a mock cellular network. I am using an Agilent E6621A PXT Wireless Communications Test Set, which supports wireless LTE connections to any smartphone with the right configuration. I am trying to set up a mock cellular network that simulates VoLTE by utilizing FreePBX as the SIP server.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |